Necessities Types Of Bakery Products List Bakery Machinery Water Chiller
1.The main engine of water chiller is using the imported famous brand compressor, and the system is using the high quality environmental protection refrigerant, energy saving safety and no pollution, reliable operation, high efficiency, low noise.
2.Water chiller Adopt the high precision microcomputer control technology, accurate temperature control, with the multiple protection for the high and low pressure, overload of the compressor and the setting flow protection switch, if the water pump goes wrong or the water flow rate be too small,the safe operation will be protected by the the flow switch automatically, high reliability.
Bakery machinery Water Chiller
About R&M Water Chiller
1.The main engine of water chiller is using the imported famous brand compressor, and the system is using the high quality environmental protection refrigerant, energy saving safety and no pollution, reliable operation, high efficiency, low noise.
2.Water chiller Adopt the high precision microcomputer control technology, accurate temperature control, with the multiple protection for the high and low pressure, overload of the compressor and the setting flow protection switch, if the water pump goes wrong or the water flow rate be too small,the safe operation will be protected by the the flow switch automatically, high reliability.
3.With the optional temperature control (temperature control and fixed temperature control) and the alternative start-up mode (local panel on / off and on-line remote on / off), reliable fault alarm and protection function to protect the main machine under the safe work environment.
4.Water chiller using the stainless steel water tank evaporator to prevent any solid and other metal impurities caused during the process of water delivery.
5.Stainless steel shell, looks beautiful and easily to dismount, easy to use.
Specification of R&M Water Chiller
Model | Voltage | Refrigeration Capacity | Compressor Power | Water Pump Power | Temp.Range | Size (mm) | Weigh |
RML-100 | 220/380 v | 3.0kw 2580 kcal/h |
0.75 KW (1HP) | 0.37 KW (0.5 HP) |
Room Temp. -5℃ | 800x540x950 | 100kg |
RML-200 | 220/380 v | 5.8kw 4988 kcal/h |
1.5 KW (1HP) | 810x600x1285 | 150g.
|
Attention for installation:
Note: The best environmental temperature for the machine’s installation is under 35 degrees and placing a good ventilation environment which away from dust, humidity, direct sunlight to make the machine show the maximum performance.Please follow the relevant regulations construction to make the power, load and the grounding part.
- Transport and installation of attention points
- Please do not dump or impact the machine during the transportation process.
- Please install the machine in the place which without the sunlight or the heating source, maintaining the good ventilation and away from the dust to ensure have a good working environment for the water chiller.
3.Please keep clean for the cold water machine surface, and regularly clean the condenser air filter to ensure that without dust.
B)Please check if below items are correct or not when at the first operation
- Check the related voltage and the phase is suitable for this model,please refer to the nameplate’s detail,the power of the water chiller is used in single phase and three-phase power supply,with the voltage can be single phase/three phase,the voltage with 1 PHASE 220V/50HZ,3PHASE 220V/50HZ,3 PHASE 380V/50HZ,4 PHASE 380V/50HZ(with the zero line)The power phase is R.S.T, the neutral line (zero line) N, the ground wire is E.
- Check the water injection of the water tank if it is reached to over the inlet position or not.
- Check the water tank is locked tightly and be connected correctly or not, Using the high pure water and chooseing the pipe diameter which can meet the requirements to prevent to produce abnormal sound caused from the overload of the pump motor.
- When entering to the temperature control function, adjusting the temperature of the cold water which required by the laser equipment, the temperature difference, the compressor current setting value and the compressor start delay time.
- Please try to avoid the water pump working without the water.
- When the water pump operate for the establishment of the normal water cycle, the micro controller received the correct information of the water cycle to give the compressor action instructions, after delay to start to work.
Our Service
1.To satisfy one-stop convenience for our client, our company presented service of matching kitchen equipment.
2.We offers OEM & ODM services. Our company has strong ability to design and manufacture, with more than 13 years of business experience.
3.Customized according to the different needs of customers, such as the energy consumption of diesel, electric and gas.
4.We can offer the spare parts according to your order. One year warranty.
5.You have flexibility to choose the payment terms that work best for your budget.
6. We offers profession consultancy and solution to customers.
7. Packed in protective wooden case to ensure the safety of transportation. All our product can be packed as you need.
8.With CE & ISO9001 certification.
8.Factory direct sale price. Quality assurance.
Seng Inquiry To Us
- Product Details
-
Bakery machinery Water Chiller
About R&M Water Chiller
1.The main engine of water chiller is using the imported famous brand compressor, and the system is using the high quality environmental protection refrigerant, energy saving safety and no pollution, reliable operation, high efficiency, low noise.
2.Water chiller Adopt the high precision microcomputer control technology, accurate temperature control, with the multiple protection for the high and low pressure, overload of the compressor and the setting flow protection switch, if the water pump goes wrong or the water flow rate be too small,the safe operation will be protected by the the flow switch automatically, high reliability.
3.With the optional temperature control (temperature control and fixed temperature control) and the alternative start-up mode (local panel on / off and on-line remote on / off), reliable fault alarm and protection function to protect the main machine under the safe work environment.
4.Water chiller using the stainless steel water tank evaporator to prevent any solid and other metal impurities caused during the process of water delivery.
5.Stainless steel shell, looks beautiful and easily to dismount, easy to use.
Specification of R&M Water Chiller
Model Voltage Refrigeration Capacity Compressor Power Water Pump Power Temp.Range Size (mm) Weigh RML-100 220/380 v 3.0kw
2580 kcal/h0.75 KW (1HP) 0.37 KW
(0.5 HP)Room Temp. -5℃ 800x540x950 100kg RML-200 220/380 v 5.8kw
4988 kcal/h1.5 KW (1HP) 810x600x1285 150g. Attention for installation:
Note: The best environmental temperature for the machine’s installation is under 35 degrees and placing a good ventilation environment which away from dust, humidity, direct sunlight to make the machine show the maximum performance.Please follow the relevant regulations construction to make the power, load and the grounding part.
- Transport and installation of attention points
- Please do not dump or impact the machine during the transportation process.
- Please install the machine in the place which without the sunlight or the heating source, maintaining the good ventilation and away from the dust to ensure have a good working environment for the water chiller.
3.Please keep clean for the cold water machine surface, and regularly clean the condenser air filter to ensure that without dust.
B)Please check if below items are correct or not when at the first operation
- Check the related voltage and the phase is suitable for this model,please refer to the nameplate’s detail,the power of the water chiller is used in single phase and three-phase power supply,with the voltage can be single phase/three phase,the voltage with 1 PHASE 220V/50HZ,3PHASE 220V/50HZ,3 PHASE 380V/50HZ,4 PHASE 380V/50HZ(with the zero line)The power phase is R.S.T, the neutral line (zero line) N, the ground wire is E.
- Check the water injection of the water tank if it is reached to over the inlet position or not.
- Check the water tank is locked tightly and be connected correctly or not, Using the high pure water and chooseing the pipe diameter which can meet the requirements to prevent to produce abnormal sound caused from the overload of the pump motor.
- When entering to the temperature control function, adjusting the temperature of the cold water which required by the laser equipment, the temperature difference, the compressor current setting value and the compressor start delay time.
- Please try to avoid the water pump working without the water.
- When the water pump operate for the establishment of the normal water cycle, the micro controller received the correct information of the water cycle to give the compressor action instructions, after delay to start to work.
- Service
-
Our Service
1.To satisfy one-stop convenience for our client, our company presented service of matching kitchen equipment.
2.We offers OEM & ODM services. Our company has strong ability to design and manufacture, with more than 13 years of business experience.
3.Customized according to the different needs of customers, such as the energy consumption of diesel, electric and gas.
4.We can offer the spare parts according to your order. One year warranty.
5.You have flexibility to choose the payment terms that work best for your budget.
6. We offers profession consultancy and solution to customers.
7. Packed in protective wooden case to ensure the safety of transportation. All our product can be packed as you need.
8.With CE & ISO9001 certification.
8.Factory direct sale price. Quality assurance. - Contact
-
Seng Inquiry To Us